OTA Update Flow

See also: Controller OTA Updates for device-side configuration, request headers, and firmware payload format.

Overview

Devices check for firmware updates by calling GET /ota/{product_id}/{application}?current_version={version}. The current_version parameter is required — omitting it returns 400 Bad Request.

The endpoint returns the next available version for the device to install, not the latest one. This ensures controlled, sequential upgrades. A device on 2026.01.01 installs 2026.02.01 first, then 2026.03.01 on its next check — never jumping multiple versions in one step.

Sequential updates protect against skipping intermediate versions that may contain breaking data migrations or hardware configuration changes required before later versions can run successfully.

How Versioning Works

Version strings use the format YYYY.MM.bb (e.g., 2026.03.01), where MM is the two-digit month and bb is the two-digit build number within that month. DynamoDB stores version as the sort key on the {product_id}#{application} partition, so RELEASED builds are ordered oldest-to-newest by lexicographic string sort — which matches chronological order given this format.

The endpoint finds the oldest RELEASED version whose version string is strictly greater than current_version. If no such version exists, the device is at or beyond the latest released version — see response codes below for the exact outcome.

Response Codes

ConditionResponse
current_version query param missing400 Bad Request
No RELEASED firmware exists for this product/application404 Not Found
A newer RELEASED version is available200 OK with the next version's manifest
Device is already on the latest RELEASED version200 OK with the current version's manifest (semver_compare == 0; device does not update)
Device's current version is REVOKED and nothing newer is RELEASED409 Conflict

Note on 200 with the same version: The BrentIO/esp32FOTA library always expects HTTP 200 from the manifest endpoint. It decides whether to update by comparing the returned version against the running version using semver_compare. Equal versions (semver_compare == 0) cause no update. The library treats any non-200 response as a hard error — a 404 is not a graceful "you're up to date" signal.


Scenario 1: Normal Sequential Update

Released firmware for FFC3232-2603 / Controller:

VersionStatus
2026.01.01RELEASED
2026.02.01RELEASED
2026.03.01RELEASED

Update cycle for a device currently on 2026.01.01:

  1. GET /ota/FFC3232-2603/Controller?current_version=2026.01.01
    • Next RELEASED version > 2026.01.01 is 2026.02.01
    • Response: 200 with manifest for 2026.02.01
  2. Device installs 2026.02.01 and reboots.
  3. GET /ota/FFC3232-2603/Controller?current_version=2026.02.01
    • Next RELEASED version > 2026.02.01 is 2026.03.01
    • Response: 200 with manifest for 2026.03.01
  4. Device installs 2026.03.01 and reboots.
  5. GET /ota/FFC3232-2603/Controller?current_version=2026.03.01
    • No RELEASED version > 2026.03.01 exists; 2026.03.01 is still RELEASED
    • Response: 200 with manifest for 2026.03.01 (same version — device does not update)

Scenario 2: Device That Did Not Update When a Version Was Available

A device was online when 2026.01.01 was the latest, but did not install it. Now 2026.02.01 and 2026.03.01 are also RELEASED. The device is still on its factory firmware 2025.12.01.

  1. GET /ota/FFC3232-2603/Controller?current_version=2025.12.01
    • All three RELEASED versions are > 2025.12.01; oldest is 2026.01.01
    • Response: 200 with manifest for 2026.01.01
  2. Device installs 2026.01.01 and continues through the normal sequential flow.

Scenario 3: Firmware Revoked Before Device Installed It

2026.01.01 is revoked after release but before all devices have installed it.

Firmware table:

VersionStatus
2026.01.01REVOKED
2026.02.01RELEASED
2026.03.01RELEASED

Device on 2026.02.01 (checking for updates):

  1. GET /ota/FFC3232-2603/Controller?current_version=2026.02.01
    • Response: 200 with manifest for 2026.03.01 (next RELEASED)

Device still on factory firmware 2025.12.01 that never installed 2026.01.01:

  1. GET /ota/FFC3232-2603/Controller?current_version=2025.12.01
    • RELEASED versions > 2025.12.01: 2026.02.01, 2026.03.01 (2026.01.01 is REVOKED, excluded)
    • Response: 200 with manifest for 2026.02.01 (oldest RELEASED > current)
  2. Device skips the revoked version cleanly and installs 2026.02.01.

Scenario 4: Device Currently Running Revoked Firmware — Newer Version Available

2026.02.01 is revoked after some devices installed it. 2026.03.01 is still RELEASED.

Device on 2026.02.01 (the now-revoked version):

  1. GET /ota/FFC3232-2603/Controller?current_version=2026.02.01
    • RELEASED versions > 2026.02.01: 2026.03.01
    • Response: 200 with manifest for 2026.03.01
  2. Device installs 2026.03.01 and reboots.
  3. GET /ota/FFC3232-2603/Controller?current_version=2026.03.01
    • Response: 200 with manifest for 2026.03.01 (same version; device does not update)

Scenario 5: Device Running Revoked Firmware — No Newer Version Released

2026.03.01 is the latest version and is REVOKED. No replacement has been released yet.

Device on 2026.03.01:

  1. GET /ota/FFC3232-2603/Controller?current_version=2026.03.01
    • No RELEASED version > 2026.03.01 exists
    • 2026.03.01 is not in RELEASED (it is REVOKED)
    • Response: 409 Conflict
  2. Device receives a non-200 response (treated as lastHTTPCheckStatus::HTTP_ERROR by esp32FOTA). A new firmware must be released before this device can self-update.

Scenario 6: Multiple Product IDs

The product_id and application path parameters together form the DynamoDB partition key ({product_id}#{application}). OTA queries are strictly scoped to that combination — firmware for one product is never served to another.

Example: Two product lines share the same application name.

product_idapplicationVersionStatus
FFC3232-2603Controller2026.01.01RELEASED
FFC3232-2603Controller2026.02.01RELEASED
FFC3232-2604Controller2026.01.01RELEASED
  • GET /ota/FFC3232-2603/Controller?current_version=2026.01.01200 with 2026.02.01
  • GET /ota/FFC3232-2604/Controller?current_version=2026.01.01200 with 2026.01.01 (same version; no update — only one version released for this product)

Library Dependency

The BrentIO/esp32FOTA library does not currently append current_version to the manifest URL. The library must be updated to add a use_current_version config flag that, when enabled, appends ?current_version=<version> to the manifest URL before issuing the GET request — mirroring the existing use_device_id pattern that appends ?id=<mac>.

Until this library update is made, the server cannot perform sequential version delivery.